[Comparative study of deep lying drusen of the papilla with the scanning laser ophthalmoscope and fundus camera]
Related Experiment Videos
J K Schön1, J E Nasemann, K P Boergen
1Augenklinik der Universität Regensburg.
Abstract:
We examined four patients with the suspected diagnosis of optic disc drusen by scanning laser ophthalmoscopy (SLO) and fundus photography. In all four cases the autofluorescence that distinguishes optic disc drusen was observed with the SLO, but not with the fundus camera. Three of the four examined patients, children or adolescents, were spared further diagnostic procedures to clarify the underlying cause of the swollen optic disc.