Dose calibration of nonconventional treatment systems applied to helical tomotherapy
Robert Jeraj1, Thomas R Mackie, John Balog
1Department of Medical Physics, University of Wisconsin-Madison, Madison, Wisconsin 53706, USA.
Abstract:
Current dosimetric protocols based on the absorbed dose (AAPM TG-51 and IAEA TRS-398 protocols) require calibration measurements under reference conditions. For some radiotherapy systems, this requirement cannot be met, and calibration has to be performed under nonreference experimental conditions. In order to solve this problem, both protocols can be extended by inclusion of the measured-to-reference conversion factor, k(mr). In order to determine this factor, basic dosimetric quantities, like stopping power ratios, mass attenuation coefficients and chamber correction factors have to be calculated. If measurements are not feasible, accurate Monte Carlo modeling is required. The extension of the protocols is illustrated using the case of the helical tomotherapy radiation unit, where the typical calibration measurement conditions are the 10 x 5 cm2 field size and the 85 cm surface source distance, limited by the system design. It was calculated that the k(mr) factor for this conditions is close to unity (0.997+/-0.001). In addition, the deviation of the measurement conditions from the reference conditions results in the change of the quality conversion factor (approximately 0.995-0.998, depending on the ionization chamber used). This change is the same regardless of the used calibration protocol. For smaller field sizes the corrections become more significant, resulting in the total correction factor compared to the reference conditions of up to 1.5% for the smallest considered field size of 2 x 2 cm2.
More Related Videos
08:54Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses