Related Experiment Video
Updated: Aug 18, 2026

Isolation of Human Atrial Myocytes for Simultaneous Measurements of Ca2+ Transients and Membrane Currents
Published on: July 3, 2013
Ionic determinants of functional reentry in a 2-D model of human atrial cells during simulated chronic atrial
Sandeep V Pandit1, Omer Berenfeld, Justus M B Anumonwo
1Institute for Cardiovascular Research and Department of Pharmacology, State University of New York Upstate Medical University, Syracuse, NY 13210, USA.
Abstract:
Recent studies suggest that atrial fibrillation (AF) is maintained by fibrillatory conduction emanating from a small number of high-frequency reentrant sources (rotors). Our goal was to study the ionic correlates of a rotor during simulated chronic AF conditions. We utilized a two-dimensional (2-D), homogeneous, isotropic sheet (5 x 5 cm(2)) of human atrial cells to create a chronic AF substrate, which was able to sustain a stable rotor (dominant frequency approximately 5.7 Hz, rosette-like tip meander approximately 2.6 cm). Doubling the magnitude of the inward rectifier K(+) current (I(K1)) increased rotor frequency ( approximately 8.4 Hz), and reduced tip meander (approximately 1.7 cm). This rotor stabilization was due to a shortening of the action potential duration and an enhanced cardiac excitability. The latter was caused by a hyperpolarization of the diastolic membrane potential, which increased the availability of the Na(+) current (I(Na)). The rotor was terminated by reducing the maximum conductance (by 90%) of the atrial-specific ultrarapid delayed rectifier K(+) current (I(Kur)), or the transient outward K(+) current (I(to)), but not the fast or slow delayed rectifier K(+) currents (I(Kr)/I(Ks)). Importantly, blockade of I(Kur)/I(to) prolonged the atrial action potential at the plateau, but not at the terminal phase of repolarization, which led to random tip meander and wavebreak, resulting in rotor termination. Altering the rectification profile of I(K1) also slowed down or abolished reentrant activity. In combination, these simulation results provide novel insights into the ionic bases of a sustained rotor in a 2-D chronic AF substrate.
Related Concept Videos
Electrophysiology of Normal Cardiac Rhythm
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Mechanism of Cardiac Arrhythmias
Cardiac Action Potential
The cardiac action potential process involves a series of phases characterized by the movement of ions across the cardiac cell membranes, leading to the depolarization and repolarization of the cardiac myocytes.
Ionic Basis of Cardiac Action Potentials
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow heart...

