[Analysis of residual solvents in natural flavorings by headspace GC using the standard addition method]
Kyoko Sato1, Yoko Uematsu, Satoshi Isagawa
1National Institute of Health Sciences, Tokyo, Japan.
Abstract:
Headspace GC using the standard addition method has been developed for the simultaneous determination of organic solvents in natural flavorings. The procedure can be outlined as follows: an aliquot of the sample is transferred to a 10 mL vial. To each vial, a DMSO solution containing solvents at different concentrations is added as the standard solution. The vials are kept at 50 degrees C (for automatic injection) or 40 degrees C (for hand-operated injection) for 40 minutes. One mL of the vapor phase in each vial is injected into a gas chromatograph equipped with an Aquatic-2 column (0.25 mm i.d. x 60 m). To evaluate this method, we conducted a performance study in collaboration with 10 laboratories, using ginger oleoresin. We analyzed 6 solvents (methanol, 2-propanol, acetone, dichloromethane, hexane, and 1,1,2-trichloroethene) for which the maximum residue limits are established in Japan's Specifications and Standards for Food Additives. Methanol and acetone existed in the ginger oleoresin, so only the other that four kinds of solvents were added to it. Eight of the laboratories used automatic injection, while the remaining two used hand-operated injection. Statistical analyses were conducted on the data obtained from the 8 laboratories. Repeatability standard deviations (RSDr) ranged from 4.3 to 11.4%, and reproducibility standard deviations (RSDR) ranged from 8.4 to 19.0%.
More Related Videos
05:29Profiling Volatile Compounds in Blackcurrant Fruit using Headspace Solid-Phase Microextraction Coupled to Gas Chromatography-Mass Spectrometry
Published on: June 9, 2021
05:22Rapid Collection of Floral Fragrance Volatiles using a Headspace Volatile Collection Technique for GC-MS Thermal Desorption Sampling
Published on: December 10, 2019
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Supercritical Fluid Chromatography
SFC utilizes a supercritical fluid mobile phase,...