Development and validation of a simple, sensitive, second antibody format enzyme immunoassay (EIA) for LH
Mohan Mondal1, Arindam Dhali, Bhukya Prakash
1National Research Centre on Mithun (ICAR), Jharnapani, Medziphema, Nagaland-797 106, India. mohan_mondal@rediffmail.com
Abstract:
The objective of this study was to develop and validate a simple and highly sensitive enzyme immunoassay (EIA) for LH determination in mithun plasma on microtitreplates using the biotin-streptavidin amplification system and the second antibody coating technique. Biotin was coupled to LH and used to bridge between streptavidin-peroxidase and immobilized antiserum in competitive assay. The EIA was carried out directly in 20 microL mithun plasma. The LH standards ranging from 6.25 pg/well/20 microL to 400 pg/well/20 microL were prepared in hormone free plasma collected from a mithun on day 3 post calving. The sensitivity of EIA procedure was 6.25 pg/well LH, which corresponds to 0.31 ng/mL plasma; the 50 percent relative binding sensitivity was seen at 100 pg/well/20 microL. Plasma volumes for the EIA viz. 10 and 20 microL did not influence the shape of standard curve even though a slight drop in the OD450 was seen with higher plasma volumes. A parallelism test was carried out to compare the endogenous mithun plasma LH with bovine LH standards. It showed good parallelism with the bovine standard curve. For the biological validation of the assay, 3 mithuns were used. These were administered 10 microg i.v., with a synthetic analogue of GnRH (Buserelin-Acetate, Intervet, India) and blood samples were collected at 15 min intervals using indwelling jugular catheter beginning 1 h prior to GnRH injection till 8 h post injection. In all animals, sharp increases in LH concentrations were recorded post GnRH administration, which confirms the biological validation of the EIA. In conclusion, the EIA developed for LH determination in mithun blood plasma is sufficiently reliable, economical, and sensitive enough to estimate LH in all physiological variations in mithun.
More Related Videos
08:26Development and Validation of an Ultrasensitive Single Molecule Array Digital Enzyme-linked Immunosorbent Assay for Human Interferon-α
Published on: June 14, 2018
06:50A High-Throughput Electrochemiluminescence 7-Plex Assay Simultaneously Screening for Type 1 Diabetes and Multiple Autoimmune Diseases
Published on: May 29, 2020