Related Experiment Video
Updated: Aug 18, 2026

Measurement of Aerosols Optical Thickness of the Atmosphere using the GLOBE Handheld Sun Photometer
Published on: May 29, 2019
Stratospheric temperature monitoring using a vibrational Raman lidar. Part 1: aerosols and ozone interferences
Denis Faduilhe1, Philippe Keckhut, Hassan Bencherif
1Laboratoire de Physique de l'Atmosphère, Centre National de la Recherche Scientifique, Université de La Réunion, 15 Avenue René Cassin, 97715 Saint-Denis Messag Cedex 9, La Réunion, France. denis.faduilhe@univ-reunion.fr
Abstract:
Lidar measurements of temperature for the upper troposphere and lower stratosphere are commonly derived by the Raman technique. Lidar signals derived from vibrational Raman processes have been subjected to numerous simulation tests to examine their sensitivity to the presence of aerosols and ozone in the atmosphere. The influence of aerosols characteristics (wavelength dependence of aerosol extinction and particle phase function) and of ozone concentration on Raman temperature profiles is estimated. Simulations indicate large temperature deviations for post-volcanic conditions. For a Raman backscatter at 607 nm, bias is below 1 K for a total optical depth less than 9 x 10(-3) in the case of a stratospheric contamination and less than 6 x 10(-3) for a tropospheric contamination. The effect of aerosols depends on phase function and a few parameters such as altitude, optical depth and the shape of the high-altitude cloud. The wavelength dependence of aerosol extinction has some influence only for severe post-volcanic conditions (Scattering Ratio, SR >2). For a Raman backscatter at 387 nm, bias is larger and can be significant even in background aerosol conditions. Changes in the ozone density profile lead to significant Raman temperature deviations only for some specific conditions. Results suggest that both aerosol and ozone corrections are necessary to obtain an accuracy better than the 1 K requested for most atmospheric applications.
Related Concept Videos
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature from...
Atomic Absorption Spectroscopy: Atomization Methods
Boundary Layer Characteristics
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...