Determination of Cardiac Output in a Porcine Model for Ex Vivo Pulmonary Perfusion
Published on: June 28, 2024
Central venous-arterial carbon dioxide difference as an indicator of cardiac index
Joseph Cuschieri1, Emanuel P Rivers, Michael W Donnino
1Department of Surgery, Henry Ford Health Systems, Detroit, MI, USA.
Objective:
The mixed venous-arterial (v-a) pCO(2) difference has been shown to be inversely correlated with the cardiac index (CI). A central venous pCO(2), which is easier to obtain, may provide similar information. The purpose of this study was to examine the correlation between the central venous-arterial pCO(2) difference and CI.
Design:
Prospective, cohort study.
Setting:
Intensive care unit of an urban tertiary care hospital.
Patients And Participants:
Eighty-three consecutive intensive care unit patients.
Measurements:
Simultaneous blood gases from the arterial, pulmonary artery (PA), and central venous (CV) catheters were obtained. At the same time point, cardiac indices were measured by the thermodilution technique (an average of three measurements). The cardiac indices obtained by the venous-arterial differences were compared with those determined by thermodilution.
Results:
The correlation (R(2)) between the mixed venous-arterial pCO(2) difference and cardiac index was 0.903 (p <0.0001), and the correlation between the central venous-arterial pCO(2) difference and cardiac index was 0.892 (p <0.0001). The regression equations for these relationships were natural log (CI)=1.837-0.159 (v-a) CO(2) for the PA and natural log (CI)=1.787-0.151 (v-a) CO(2) for the CV (p <0.0001 for both). The root-mean-squared error for the PA and CV regression equations were 0.095 and 0.101, respectively.
Conclusion:
Venous-arterial pCO(2) differences obtained from both the PA and CV circulations inversely correlate with the cardiac index. Substitution of a central for a mixed venous-arterial pCO(2) difference provides an accurate alternative method for calculation of cardiac output.
Related Concept Videos
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Cardiac Output and Stroke Volume
In an average resting adult male, the typical cardiac output averages...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Carbon Dioxide Transport in the Blood
Forms of CO2 Transport
1. Dissolved in plasma: A small percentage (7-10%) of CO2 is transported and dissolved directly in the plasma.
2. Carbaminohemoglobin: Just over 20% of CO2 is chemically bound to...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Cardiac Output II: Effect of Stroke Volume on Cardiac Output
Preload
Preload refers to the initial elongation of the cardiac myocytes before contraction and is related to the volume of blood filling the heart at the end of diastole, or end-diastolic volume. The...