Related Experiment Video
Updated: Aug 18, 2026

Evaluating Regional Pulmonary Deposition using Patient-Specific 3D Printed Lung Models
Published on: November 11, 2020
In vitro study and semiempirical model for aerosol delivery control during mechanical ventilation
Laurent Vecellio1, Claude Guérin, Daniel Grimbert
1INSERM U-618 IFR 135, Université François-Rabelais, 37000 Tours, France. vecellio@med.univ-tours.fr
Abstract:
The object of this study was to evaluate in vitro the influence of various ventilatory parameters on the delivery of synchronized nebulization of terbutaline during mechanical ventilation and to determine a semiempirical model to control the quantity of aerosol delivered into the patient's lung. An ATOMISOR NL9 M jet nebulizer (La Diffusion Technique Francaise, France) was filled with terbutaline (Bricanyl, Astra-Zeneca, Sweden) and connected to the inspiratory line of a Horus ventilator (Taema, France). Nebulization was synchronized with the inspiratory phase. We assessed at the end of the endotracheal tube the quantity of terbutaline (terbutaline mass output) and the volume median diameter (VMD) by diffraction-laser method. There was a negative correlation between terbutaline mass output and inspiratory air flow ( r =-0.95, p <0.0001) and between VMD and inspiratory air flow ( r =-0.96, p <0.0001). Moreover, positive end-expiratory pressure levels between 0 cm and 8 cm of water did not significantly change the terbutaline output mass ( p =0.22). Total nebulization time and terbutaline mass output calculated by the mathematical model showed good agreement with experimental data. In conclusion, our semiempirical model allows calculation of the duration of the nebulization required to deliver a given mass of terbutaline into patient lungs.
More Related Videos
15:04Modeling and Simulations of Olfactory Drug Delivery with Passive and Active Controls of Nasally Inhaled Pharmaceutical Aerosols
Published on: May 20, 2016
07:28Dry Powder and Nebulized Aerosol Inhalation of Pharmaceuticals Delivered to Mice Using a Nose-only Exposure System
Published on: April 6, 2017
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Mechanical Ventilation I: Indication and Settings
Ventilatory Modes
There are three ventilatory modes: full support, partial support, and spontaneous. These are described below.
Full Support Modes
Full support modes include controlled mechanical ventilation, continuous mandatory...