Use of a Percutaneous Ventricular Assist Device/Left Atrium to Femoral Artery Bypass System for Cardiogenic Shock
Published on: August 16, 2021
Worldwide clinical experience with the CorCap Cardiac Support Device
Randall C Starling1, Mariell Jessup
1Section of Heart Failure and Cardiac Transplant Medicine, Kaufman Center for Heart Failure, Cleveland Clinic Lerner College of Medicine, Cleveland, Ohio 44195, USA.
Insights
The CorCap Cardiac Support Device (CSD) shows promise in reducing left ventricular (LV) size and improving ejection fraction in heart failure patients. Early studies indicate sustained benefits and safe implantation, suggesting potential for improved cardiac performance.
Area of Science:
- Cardiology
- Biomedical Engineering
- Medical Devices
Background:
- Left ventricular (LV) remodeling increases myocardial wall stress, impairing cardiac function and worsening heart failure.
- The CorCap Cardiac Support Device (CSD) is designed to mitigate these effects by providing external myocardial support.
Purpose of the Study:
- To evaluate the safety and efficacy of the CorCap CSD in patients with advanced heart failure.
- To assess the device's impact on LV dimensions, ejection fraction, and clinical status.
Main Methods:
- Initial safety studies involved 48 patients, followed by a randomized controlled trial with 300 patients.
- The trial included arms for mitral valve surgery with CSD and cardiomyopathy with medical therapy alone or with CSD.
- Primary endpoint was a change in clinical composite score from baseline.
Main Results:
- Initial studies showed significant and sustained reductions in LV end-diastolic dimension post-CSD implantation.
- LV ejection fraction significantly improved and was maintained for up to 3 years.
- Hemodynamic data revealed no evidence of constrictive physiology, and implantation was safe.
Conclusions:
- The CorCap CSD can be safely implanted in heart failure patients, demonstrating significant improvements in LV size and function.
- The device shows potential for improving cardiac performance and managing advanced heart failure.
- CE mark approval in Europe and limited market release indicate ongoing clinical evaluation.
Abstract:
It has been hypothesized that the mechanical burden associated with LV remodeling leads to increased myocardial wall stress and adverse remodeling, all of which serve to further impair cardiac performance and contribute to disease progression. The CorCap Cardiac Support Device (CSD) (Acorn Cardiovascular, Inc., St. Paul, Minnesota) is a mesh-like device that is surgically implanted around the heart. The device is designed to provide circumferential myocardial wall support, and reduce wall stress and myocyte stretch. Clinical experience with CorCap CSD implants in patients with heart failure can be divided into 3 phases: (1) initial safety studies, (2) randomized controlled trials, and (3) limited marketed release. Initial safety studies were undertaken in 48 patients recruited between April 1999 and April of 2001. In 11 patients with complete follow-up, it was noted that LV size, as measured by LV end-diastolic dimension, significantly decreased as early as 3 months postimplant, with an even greater reduction at 6 months. Most importantly, this benefit was sustained, so that the LV end-diastolic dimension stayed smaller at 1, 2, and 3 years of follow-up. There was also an improvement in LV function, as manifested by changes in LV ejection fraction. Ejection fraction was significantly increased by 3 months and appeared to reach a peak improvement by 6 months. This benefit was likewise maintained at 1, 2, and 3 years postsurgery. Hemodynamic data did not show any evidence of constrictive physiology. These preliminary safety studies had shown that the CorCap CSD could be implanted safely and without excess operative morbidity or mortality. The primary objective of the Acorn Randomized Clinical Trial is to assess the efficacy and safety of the CorCap CSD in patients with advanced heart failure despite optimal medical therapy. A randomized trial with 2 arms (mitral valve surgery randomized to CSD and cardiomyopathy randomized to medical therapy alone or with CSD) enrolled 300 patients. The primary endpoint of the trial is a change in clinical status from baseline to the end of the efficacy phase as determined by a clinical composite score. The Acorn CorCap CSD received CE mark approval in Europe in 2001 and has been available to a small number of centers in a Limited Market Release Surveillance Study (LMRSS).