Related Experiment Video
Updated: Aug 18, 2026

Method and Instrumented Fixture for Femoral Fracture Testing in a Sideways Fall-on-the-Hip Position
Published on: August 17, 2017
Out on a limb: risk factors for arm fracture in playground equipment falls
S Sherker1, J Ozanne-Smith, G Rechnitzer
1NSW Injury Risk Management Research Centre, University of New South Wales, Sydney, NSW 2052, Australia. Shauna.Sherker@unsw.edu.au
Objectives:
To investigate and quantify fall height, surface depth, and surface impact attenuation as risk factors for arm fracture in children who fall from playground equipment.
Design:
Unmatched case control study.
Setting:
Five case hospitals and 78 randomly selected control schools.
Participants:
Children aged less than 13 years in Victoria, Australia who fell from school playground equipment and landed on their arm. Cases sustained an upper limb fracture and controls had minor or no injury. A total of 402 cases and 283 controls were included.
Interventions:
Children were interviewed in the playground as soon as possible after their fall.
Main Outcome Measures:
Falls were recreated on site using two validated impact test devices: a headform (measuring peak G and HIC) and a novel anthropometric arm load dummy. Equipment and fall heights, as well as surface depth and substrate were measured.
Results:
Arm fracture risk was greatest for critical equipment heights above 1.5 m (OR 2.39, 95% CI 1.49 to 3.84, p<0.01), and critical fall heights above 1.0 m (OR 2.96, 95% CI 1.71 to 5.15, p<0.01). Peak headform deceleration below 100G was protective (OR 0.67, 95% CI 0.45 to 0.99, p = 0.04). Compliance with 20 cm surface depth recommendation was poor for both cases and controls.
Conclusions:
Arm fracture-specific criteria should be considered for future standards. These include surface and height conditions where critical headform deceleration is less than 100G. Consideration should also be given to reducing maximum equipment height to 1.5 m. Improved surface depth compliance and, in particular, guidelines for surface maintenance are required.
More Related Videos
06:00Four Temporary Waterslide Designs Adapted to Different Slope Conditions to Encourage Child Socialization in Playgrounds
Published on: December 9, 2022
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024