Background:
Despite the increasing popularity of wrist-cuff blood pressure (BP) devices, their accuracy has not been established and international guidelines do not support their use. Because arm position influences BP measurement, it is possible that conflicting reports on wrist-cuff device accuracy reflects diverse arm positions.
Method:
This study compared BP measured by two oscillometric devices, the upper arm-cuff OMRON HEM 705 CP and the OMRON R6 oscillometric wrist-cuff device. In the former BP was measured with the arm in two supported positions, dependent on a table (manufacturer's instructions) and horizontal (mid sternum), while the latter followed the manufacturer's instructions.
Results:
In contrast to the dependent arm where BP was significantly higher (P<0.05), the horizontal arm position with the arm-cuff produced a mean systolic and diastolic BP comparable to the wrist-cuff device where the wrist was at heart level being respectively, 137+/-29/80+/-16 and 134+/-27/77+/-16 mmHg. A close relationship over a wide BP range was also confirmed by least squares, least product linear regression and Bland-Altman analysis.
Conclusion:
This study supports the use of wrist-cuff monitors for self/home use and underlines the need for a more precise definition for arm position when using all BP devices -- mercury and oscillometric.
Related Concept Videos
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...