Cardiac function in borderline hypothyroidism: a study by pulsed wave tissue Doppler imaging
Related Experiment Videos
Sandra Zoncu1, Francesca Pigliaru, Claudia Putzu
1Department of Cardiovascular Sciences, University of Cagliari, Sardinia, Italy.
Objective:
In subclinical hypothyroidism (SH), impaired diastolic function has been documented at rest and on effort, while systolic dysfunction has only been assessed on effort.
Design:
The aim of the present study was: (a) to further assess systolic function at rest in SH; and (b) to ascertain whether cardiac dysfunction could precede TSH increase in euthyroid patients with a high risk of developing SH.
Methods:
We studied 32 patients with classical Hashimoto's thyroiditis (22 with increased serum TSH (> 3 mU/ml - group A), and 10 with normal serum TSH (< 3 mU/ml - group B)); a third group (C), which included 13 healthy controls. All subjects underwent pulsed wave tissue Doppler imaging (PWTDI) to accurately quantify the global and regional left ventricular function.
Results:
When compared with group C, PWTDI indices showed that in both groups A and B there was a significant impairment of systolic ejection (P < 0.001 and P < 0.05, respectively), a delay in diastolic relaxation (P < 0.001 and P < 0.05, respectively) and a decrease in the compliance to the ventricular filling (P < 0.05). Several significant correlations were found between PWTDI parameters and serum-free T(3) and T(4) and TSH concentrations.
Conclusion:
PWTDI is a sensitive technique that allows detection of both diastolic and systolic abnormalities, not only in patients with SH, but also in euthyroid subjects with a high risk of developing thyroid failure. Futhermore, the significant correlations of several PWTDI indices with serum FT(3) and TSH concentrations strongly support the concept of a continuum spectrum of a slight thyroid failure in autoimmune thyroiditis extending to subjects with serum TSH still within the normal range.
Related Concept Videos
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Dysrhythmias V: Evaluating Dysrhythmias
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...