Related Experiment Video
Updated: Aug 18, 2026

Computed Tomography-guided Time-domain Diffuse Fluorescence Tomography in Small Animals for Localization of Cancer Biomarkers
Published on: July 17, 2012
18F-fluoro-2-deoxy-D-glucose positron emission tomographic imaging: recent developments in head and neck cancer
Kristoff Muylle1, Catherine Castaigne, Patrick Flamen
1Department of Nuclear Medicine, Jules Bordet Institute, Brussels, Belgium. kristoff.muylle@bordet.be
Purpose Of Review:
Positron emission tomography using 18F-fluoro-2-deoxy-D-glucose (18FDG-PET) is well established in clinical routine as a metabolism-based whole-body imaging tool for cancer diagnosis and follow-up. Several reports have appeared indicating the potential and limitations of this technique in head and neck cancer (HNC). This review limits its scope to the recent advances using 18FDG-PET in the clinical management of HNC.
Recent Findings:
The combination of 18FDG-PET and sentinel node biopsy has been explored for the surgical treatment planning of oral and oropharyngeal cancer. Recent reports indicate that multimodality imaging combining PET with high-end CT scanning increases the diagnostic accuracy. 18FDG-PET has a potential for use in radiation treatment planning and for the prediction of response and early evaluation of treatment efficacy.
Summary:
Increasingly 18FDG-PET is used as a clinical imaging modality in the different stages of the management of HNC. In particular, its clinical value in initial staging of neck lymph nodes and in the evaluation of recurrent or residual disease is well established. In these settings 18FDG-PET has been shown to be more accurate than conventional imaging. Recent studies indicate that 18FDG-PET could be of additional value in staging the N0 neck, in radiation treatment planning, and in prediction of treatment efficacy.
More Related Videos
06:51Utilizing 18F-FDG PET/CT Imaging and Quantitative Histology to Measure Dynamic Changes in the Glucose Metabolism in Mouse Models of Lung Cancer
Published on: July 21, 2018
09:5718F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor (SiFA) for Positron Emission Tomography
Published on: January 11, 2020
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET