Related Experiment Video
Updated: Aug 14, 2026

Accurate and Simple Measurement of the Pro-inflammatory Cytokine IL-1β using a Whole Blood Stimulation Assay
Published on: March 2, 2011
Special collection and storage tubes for blood endotoxin and cytokine measurements
H Redl1, S Bahrami, G Leichtfried
1Ludwig Boltzmann Institute for Experimental and Clinical Traumatology, Vienna, Austria.
Abstract:
Commercially available blood-collection tubes may be contaminated with endotoxin (315 +/- 95 pg/tube) and could therefore be unsuitable for blood collection for endotoxin measurement. Plasma separation and storage are a potential source of contamination. To avoid contamination and error, we have developed new blood collection tubes that contain heparin free of endotoxin (LPS) and a gel to separate plasma and blood cells. The LPS content is less than 4 pg/tube. Samples can be stored and frozen without plasma withdrawal to preclude contamination. LPS recovery experiments have shown that the new blood-collection tubes do not bind LPS to the separation gel or vial wall. With these tubes, in vitro formation of tumor necrosis factor (404 +/- 163 ng/L in standard tubes vs less than 40 ng/L in special collection tubes) is minimized.