[Study on the synergistic coloration of tin (II) with pyrocatechol violet and rhodamine B and its application]

W Liu1, W Ma, B Qian

  • 1Dept. of Chemical Engineering, Huaihai Institute of Technology, 222005 Lianyungang.

Related Concept Videos

Colors and Magnetism03:02

Colors and Magnetism

Color in Coordination Complexes
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human eye.
Fixation and Sectioning01:03

Fixation and Sectioning

Two basic types of preparation are used to visualize specimens with a light microscope: wet mounts and fixed specimens.
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Aryldiazonium Salts to Azo Dyes: Diazo Coupling01:11

Aryldiazonium Salts to Azo Dyes: Diazo Coupling

The reaction of weakly electrophilic aryldiazonium (also called arenediazonium) salts with highly activated aromatic compounds leads to the formation of products with an —N=N— link, called an azo linkage. This reaction, presented in Figure 1, is known as diazo coupling and occurs without the loss of the nitrogen atoms of the aryldiazonium salt. Highly activated aromatic compounds such as phenols or arylamines favor the diazo coupling reaction. The coupling generally occurs at the para position.
Photoluminescence: Applications01:14

Photoluminescence: Applications

Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...
Redox Titration: Overview01:21

Redox Titration: Overview

Redox titration is a chemical analysis technique used to determine the concentration of an unknown substance by measuring the electron transfer in a redox (reduction-oxidation) reaction. The process involves gradually adding a titrant with a known concentration of an oxidizing or reducing agent, to the analyte, the solution with an unknown concentration, until reaching the endpoint, which indicates the completion of the reaction between the two substances. Ensuring the analyte is in a single...