Related Experiment Video
Updated: Aug 8, 2026

Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
[Non-invasive blood pressure measurement in dogs and cats]
1Hoofdafdeling Geneeskunde voor Gezelschapsdieren, Yalelaan 8, 3584 CM Utrecht en Veterinair Specialistisch Centrum 'De Wagenrenk', Keijenbergseweg 18, 6705 BN, Wageningen. p.j.j.mandigers@planet.nl
Abstract:
Bloodpressure measurements are of interest for todays veterinary practice. It can be used for screening of incoming patients, the emergency case, the intensive care patient and sedated animal. Furthermore, like in human medicine, blood pressure can be influenced by several diseases. The most reliable method of arterial blood pressure measurement is the direct or invasive method. Only the non-invasive methods doppler and oscillometric methods are used in veterinary medicine. The article describes the method of measurement, and provides a review of the literature. The oscillometric method especially in dogs. Both methods measure a lower bloodpressure if compared with an invasive method. The difference in bloodpressure is for the oscillometric method in cats greater then in dogs and appears to increase at higher blood pressures. Keeping these facts in focus, and if one is able to work in a quiet environment, repeat the measurements and maintain a critical attitude, blood pressure measurements can be performed in veterinary practice.
More Related Videos
09:38Femoral Arterial and Venous Catheterization for Blood Sampling, Drug Administration and Conscious Blood Pressure and Heart Rate Measurements
Published on: January 24, 2012
07:35Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessing Blood pressure in the Leg
Preparation:
Measurement of Blood Pressure