Related Experiment Video
Updated: Aug 18, 2026

Analyzing Protein Architectures and Protein-Ligand Complexes by Integrative Structural Mass Spectrometry
Published on: October 15, 2018
Eliminating the interferences from TRIS buffer and SDS in protein analysis by fused-droplet electrospray ionization
I-Fan Shieh1, Chi-Yang Lee, Jentaie Shiea
1Department of Chemistry, National Sun Yat-Sen University, Kaohsiung 804, Taiwan.
Abstract:
Multiply charged protein ions were detected from the solutions containing a high concentration of tris(hydroxymethyl) aminomethane buffer (TRIS) and sodium dodecyl sulfate (SDS) using fused-droplet electrospray ionization mass spectrometry (FD-ESI/MS). The sample aerosols were generated at ambient temperature with a pneumatic nebulizer commonly used to produce sample aerosols in an atmospheric pressure chemical ionization (APCI) source. The aerosols were carried by nitrogen gas to the tip of a capillary where charged methanol droplets had been continuously generated by electrospraying an acidic methanol solution. The neutral sample aerosols then fused with the charged methanol droplets and electrospray ionization proceeded from the newly formed fused droplets to generate multiply charged protein ions. Because of its low solubility in methanol, TRIS molecules (concentration as high as 1 M) were efficiently excluded from the newly formed droplets and the protein ion signals were detected and observed in the mass spectra. To remove the interferences from SDS, equal moles of positively charged cetyltrimethylammonium bromide (CTAB) was added into the SDS containing sample solution to form the dodecyl sulfate-cetyltrimethylammonium ion pair (DS-CTA). The DS-CTA ion pair has a low polarity and solubility in methanol and is excluded from the fused droplet. Protein ions were still detected from the solution containing 10(-2) M of SDS.
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Tandem Mass Spectrometry
MALDI-TOF Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...