High Precision Zinc Isotopic Measurements Applied to Mouse Organs
Published on: May 22, 2015
[Direct determination of zinc in polymerized rosin by flame atomic absorption spectrometry]
Guang Pu Xue Yu Guang Pu Fen Xi = Guang Pu
|April 14, 2005
Abstract:
Using 95% ethanol as the solvent, we directly determined zinc in polymerized rosin by flame atomic absorption spectrometry. The recovery rate is from 100 to 103 percent. The relative standard deviation (RSD) of the determination is between 1.1-4.1%. The sensitivity is high and the characteristic concentration reaches 0.0077 microg x mL(-1)/1%. The method is quite significant in forestry chemical works with its simplicity and efficiency.
Related Concept Videos
Atomic Absorption Spectroscopy: Atomization Methods
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the aerosol...
Atomic Absorption Spectroscopy: Lab
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Flame Photometry: Lab
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...