Related Experiment Video
Updated: Aug 18, 2026

Whole-body PET/MRI of Pediatric Patients: The Details That Matter
Published on: December 19, 2017
I-123 whole body scanning: case report and discussion
Herbert A Klein1, Kenneth J DiSibio, Diane Sims
1Department of Radiology, University of Pittsburgh School of Medicine, Pittsburgh, PA 15240, USA. herbert.klein@med.va.gov
Purpose:
In managing differentiated thyroid carcinoma, concern over the stunning that may occur with traditional whole body imaging using I-131 has fostered an interest in using I-123 for this purpose. A case is presented as a focus for discussion of the issues, with special reference to accuracy and the effect thereon of technical factors.
Case Report:
A 43-year-old man with papillary carcinoma of the thyroid was scanned after thyroidectomy using 10 mCi I-123. Images at 24 and 48 hours demonstrated foci including multiple regional metastases. They were less well demonstrated in images 7 days after therapeutic I-131, and negative imaging 1 year later implied therapeutic success.
Discussion:
I-131 has the advantages of a longer half-life, facilitating delayed imaging and lower price. I-123 has the advantages of favorable gamma-ray energy and less useless radiation to thyroid tissue and the whole body. Despite its short half-life, with a sufficient amount, images at 48 hours are practical. In the case presented, there are several possible reasons why superior lesion detection occurred in diagnostic I-123 images. In any case, the outcome demonstrates that I-131 posttherapy images are not an absolute "gold standard" for accuracy. Investigations comparing I-123 with I-131 imaging have been subject to biases, including insufficient dose of I-123, lack of delayed I-123 imaging, suboptimal collimation for I-131, and the relatively high dose of I-131 in posttherapy scanning.
Conclusions:
The evidence, although not definitive, strongly suggests that I-123 is at least as accurate for diagnostic whole body imaging as I-131.
More Related Videos
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy (PRRT): 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation I: X-ray and CT
Radiological Investigation II: MRI and Ventilation Perfusion Scan
Magnetic Resonance Imaging (MRI) and Ventilation Perfusion Scans are two radiological investigations that offer detailed diagnostic images of the body, particularly lung structures.
MRI
MRI uses magnetic fields and radiofrequency signals to distinguish between normal and abnormal tissues. This technology provides a more detailed diagnostic image than CT scans, enabling it to characterize pulmonary nodules, stage bronchogenic carcinoma, and evaluate inflammatory activity in...
Imaging Studies III: Computed Tomography
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...