Related Experiment Videos
Dermatologic conditions associated with use of a lower-extremity prosthesis
Nancy L Dudek1, Meridith B Marks, Shawn C Marshall
1Division of Physical Medicine and Rehabilitation, Department of Medicine, University of Ottawa, ON, Canada. ndudek@ottawahospital.on.ca
Objectives:
To document the frequency of skin problems among lower-limb prosthesis users and to assess for factors associated with skin problems among patients using a prosthesis.
Design:
Six-year retrospective chart review.
Setting:
An outpatient amputee clinic at a regional, referral rehabilitation hospital in Canada.
Participants:
Seven hundred forty-five subjects with a total of 828 lower-extremity amputations participated. Subjects were included if they had a lower-extremity amputation and used a prosthesis for ambulation or transfers.
Interventions:
Not applicable.
Main Outcome Measures:
The presence or absence of a skin problem. Descriptive and nonparametric statistics were used to analyze data.
Results:
Three hundred thirty-seven residual limbs (40.7%) had at least 1 skin problem. Adjusted odds ratios showed that amputation level, being employed, type of walking aid, and absence of peripheral vascular disease (as a comorbidity) were independently associated with the presence of at least 1 skin problem ( P <.05). CONCLUSIONS; Dermatologic conditions are a frequent complication for the lower-extremity amputee who uses a prosthesis. The results suggest that more active amputees have an increased risk for developing skin problems. Further study in this area is warranted.
Related Concept Videos
Diabetic Foot Ulcer
Peripheral Artery Disease V: Postoperative Nursing Management
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Healing II: Complications
Peripheral Artery Disease IV: Nursing Management
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above the...