Related Experiment Video
Updated: Aug 12, 2026

Uncovering Beat Deafness: Detecting Rhythm Disorders with Synchronized Finger Tapping and Perceptual Timing Tasks
Published on: March 16, 2015
Rate and synchrony in feedforward networks of coincidence detectors: analytical solution
1Zanvyl Krieger Mind/Brain Institute and Department of Neuroscience, Johns Hopkins University, Baltimore, MD 21218, USA. mikula@jhu.edu
Abstract:
We provide an analytical recurrent solution for the firing rates and cross-correlations of feedforward networks with arbitrary connectivity, excitatory or inhibitory, in response to steady-state spiking input to all neurons in the first network layer. Connections can go between any two layers as long as no loops are produced. Mean firing rates and pairwise cross-correlations of all input neurons can be chosen individually. We apply this method to study the propagation of rate and synchrony information through sample networks to address the current debate regarding the efficacy of rate codes versus temporal codes. Our results from applying the network solution to several examples support the following conclusions: (1) differential propagation efficacy of rate and synchrony to higher layers of a feedforward network is dependent on both network and input parameters, and (2) previous modeling and simulation studies exclusively supporting either rate or temporal coding must be reconsidered within the limited range of network and input parameters used. Our exact, analytical solution for feedforward networks of coincidence detectors should prove useful for further elucidating the efficacy and differential roles of rate and temporal codes in terms of different network and input parameter ranges.
Related Concept Videos
Linear time-invariant Systems
The input-output behavior of an LTI system can be fully defined by its response to an impulsive excitation at its input. Once this impulse response is known, the system's reaction to any other input can be calculated...
Aliasing
If the sampling frequency is below the Nyquist rate, these replicas overlap, preventing the original signal...
Linear Approximation in Frequency Domain
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
First Order Systems
When a first-order system is subjected to a unit-step input, its response is characterized by its transfer function. By applying the Laplace transform of the unit-step input to the transfer function, expanding the...
Second Order systems II
If ζ...
Root Loci for Positive-Feedback Systems
The construction rules for the root locus in positive feedback systems are similar to those in...

