Related Experiment Video
Updated: Aug 18, 2026

The Portable Chemical Sterilizer (PCS), D-FENS, and D-FEND ALL: Novel Chlorine Dioxide Decontamination Technologies for the Military
Published on: June 29, 2014
Inactivation of Salmonella enterica serovar Enteritidis on shell eggs by ozone and UV radiation
Luis A Rodriguez-Romo1, Ahmed E Yousef
1Department of Food Science and Technology, The Ohio State University, Columbus, Ohio 43210, USA.
Abstract:
The presence of Salmonella enterica serovar Enteritidis in shell eggs has serious public health implications. Several treatments have been developed to control Salmonella on eggs with mixed results. Currently, there is a need for time-saving, economical, and effective egg sanitization treatments. In this study, shell eggs externally contaminated with Salmonella (8.0 x 10(5) to 4.0 x 10(6) CFU/g of eggshell) were treated with gaseous ozone (O3) at 0 to 15 lb/in2 gauge for 0 to 20 min. In other experiments, contaminated shell eggs were exposed to UV radiation at 100 to 2,500 microW/cm2 for 0 to 5 min. Treatment combination included exposing contaminated eggs to UV (1,500 to 2,500 microW/cm2) for 1 min, followed by ozone at 5 lb/in2 gauge for 1 min. Eggs that were (i) noncontaminated and untreated, (ii) contaminated and untreated, and (iii) contaminated and treated with air were used as controls. Results indicated that treating shell eggs with ozone or UV, separately or in combination, significantly (P < 0.05) reduced Salmonella on shell eggs. For example, contaminated eggs treated with ozone at 4 to 8 degrees C and 15 lb/in2 gauge for 10 min or with UV (1,500 to 2,500 microW/cm2) at 22 to 25 degrees C for 5 min produced 5.9- or 4.3-log microbial reductions or more, respectively, when compared with contaminated untreated controls. Combinations including UV followed by ozone treatment resulted in synergistic inactivation of Salmonella by 4.6 log units or more in about 2 min of total treatment time. Salmonella was effectively inactivated on shell eggs in a short time and at low temperature with the use of a combination of UV radiation and ozone.
More Related Videos
Related Concept Videos
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
Methods of Sterilization II: Chemical Methods
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Methods of Sterilization I: Physical Methods
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Sources of Food Contamination

