Related Experiment Video
Updated: Aug 18, 2026

A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019
Transphyseal bioabsorbable screws cause temporary growth retardation in rabbit femur
Eero Waris1, Nureddin Ashammakhi, Christopher P Kelly
1Institute for Craniofacial and Reconstructive Surgery, Province Hospital, Southfield, MI, USA. eero.waris@helsinki.fi
Abstract:
A self-reinforced bioabsorbable poly-L-lactide/polyglycolide (SR-PLGA) 80/20 screw 2.0 mm in diameter was implanted transphyseally across the distal growth plate of the right femur in 24 immature rabbits. Radiologic evaluation revealed a mean shortening of 3.1 mm at 3 weeks, 11.1 mm at 6 weeks, 9.3 mm at 24 weeks, 9.0 mm at 48 weeks, and 12.6 mm at 72 weeks compared with the intact contralateral femur. In 13 control rabbits, drilling without screw placement did not cause any statistically significant femoral shortening. Therefore, the transphyseal SR-PLGA 80/20 screw caused growth retardation for 6 weeks postoperatively, after which the normal growth tendency was recovered until the growth plate was closed. The duration of temporary growth retardation correlated with that of strength retention of the SR-PLGA 80/20 copolymer. These findings suggest that SR-PLGA 80/20 screws can be applied in transphyseal bone fixation. The use of bioabsorbable screws for temporary epiphysiodesis seems attractive but requires further study.