Related Experiment Video
Updated: Aug 18, 2026

Comprehensive Endovascular and Open Surgical Management of Cerebral Arteriovenous Malformations
Published on: October 20, 2017
Brain arteriovenous malformations: measurement of nidal volume using a combination of static and dynamic magnetic
S Nagaraja1, D Capener, S C Coley
1Academic Radiology Section, Royal Hallamshire Hospital, University of Sheffield, Glossop Road, Sheffield, S10 2JF, UK. s.nagaraja@shef.ac.uk
Abstract:
Arteriovenous malformations of the brain are complex vascular lesions that are an important cause of death and long-term disability. Currently, catheter angiography (CA) is the reference standard procedure for the diagnosis and follow-up of treated arteriovenous malformations (AVMs). This is an invasive procedure with potential risks. Magnetic resonance angiography (MRA) is commonly used in neurovascular imaging as a non-invasive alternative. Various MRA techniques have been used in the diagnosis and follow-up of AVMs but these have suffered from lack of temporal or spatial resolution. In this 60-patient study we describe the combination of two techniques: dynamic magnetic resonance digital subtraction angiography with a high temporal resolution, and a non-dynamic contrast-enhanced time-of-flight sequence with a high spatial resolution technique, in the assessment of AVM. The results showed an excellent correlation between MRA and CA measurement of both maximum linear dimension and AVM nidus volume.