Introduction:
Nuclear medicine shuntograms using the radiotracer technetium-99m diethylenetriaminepentaacetic acid have been used for many years as an additional method to assess shunt patency and performance.
Methods:
The medical records of all children who had shuntograms performed at the Children's Hospital of Eastern Ontario between January 13, 2000, and January 10, 2003, were retrospectively reviewed. There was a total of 68 procedures in 56 patients with an average age of 9 years 3 months. During the same period there were 123 shunt revisions.
Results:
Forty-two shuntograms were reported as normal. Of these, ten were identified to be false negative. Two children with fractured shunts had shuntograms performed in order to assess for cerebrospinal fluid flow patency; the shuntograms were identified to be normal, confirming shunt dependence, and the shunt replaced. Twenty-six shuntograms were reported as abnormal in 24 patients; 17 went on to have surgery and the shunt malfunction was confirmed. Seven patients did not require surgery: five were declared shunt independent, two patients clinically improved after severe constipation was treated.
Conclusions:
Approximately one fourth of all shuntograms reported as normal are not (false-negative rate=25%). Review of five other major studies between 1980 and 2003 have reported false-negative rates between 2 and 36%, which may be explained by variations in shuntogram protocols. A standardized method is proposed.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Isotopes and Radioisotopes
An isotope containing more...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Imaging Studies III: Computed Tomography
Imaging Studies IV: Magnetic Resonance Imaging