Related Experiment Video
Updated: Aug 18, 2026

Raman and IR Spectroelectrochemical Methods as Tools to Analyze Conjugated Organic Compounds
Published on: October 12, 2018
New spectroscopic method for aqueous solutions: Raman xi-function dispersion for NaClO4 in water
1Department of Chemistry, University of Kansas, Lawrence, Kansas 66045-7582, USA.
Abstract:
A new Raman method is exemplified by xi identical with-RT[ partial differential ln(I(omega)I(REF)) partial differentialX(1)](T,P,n(2),n(3) ) for ternary NaClO(4)D(2)OH(2)O, or by xi identical with-RT[ partial differential ln(I(omega)I(REF)) partial differentialX(2)](T,P) for binary NaClO(4)H(2)O solutions. (Fundamental differences exist between xi and the chemical potential mu.) I(omega) is the Raman intensity at omega, I(REF) is the reference intensity, e.g., at the isosbestic frequency, X(2) is the H(2)O and X(1) the small D(2)O mol fraction, and n(2) and n(3) are constant mols of H(2)O and NaClO(4), respectively. Maxima (max) and minima (min) were observed in xi versus omega (cm(-1)); xi(max)-xi(min)=Deltaxi(max). Deltaxi(max)=8050+/-100 calmol H(2)O for the coupled, binary solution OH stretch, and Deltaxi(max)=4200+/-200 calmol H bond for the decoupled, ternary solution OD stretch. The perchlorate ion breaks the H bonds in water. 8050 calmol H(2)O corresponds to the maximum tetrahedral Deltaxi(max) value for two H bonds, i.e., Deltaxi(max)=4025 calmol H bond, in agreement with the HDO Deltaxi(max)=4200+/-200 calmol H bond. [Deltaxi(max) is not the H bond enthalpy (energy).] Minima occur in xi at the peak omega values corresponding to the HDOH(2)O and H(2)O ices, and maxima in xi at 2637+/-5 cm(-1) (OD) and 3575+/-10 cm(-1) (OH) correspond to the peak OD and OH stretching omega values from dense supercritical water. Enthalpy dispersion curves were also determined for saturated, binary, and ternary NaClO(4) solutions and for D(2)O in H(2)O. The xi-function method is shown to be applicable to infrared absorbance spectra.
Related Concept Videos
Raman Spectroscopy Instrumentation: Overview
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Raman Spectroscopy: Overview
However, a small fraction of the scattered light exhibits a frequency shift due to the exchange of energy between the incident photons and the...
Spectroscopy of Carboxylic Acid Derivatives
In the...
IR Spectroscopy: Hooke's Law Approximation of Molecular Vibration
According to Hooke's law, the vibrational frequency is directly proportional to the...
NMR Spectroscopy of Aromatic Compounds
NMR Spectroscopy Of Amines