Simultaneous Electrocardiography Recording and Invasive Blood Pressure Measurement in Rats
Published on: January 31, 2019
Does sequential automated measurement improve the estimate of resting blood pressure?
14th Department of Internal Medicine, Charles University, Prague, Czechoslovakia.
Abstract:
Repeated blood pressure measurements made in sequence over short time intervals have been recommended in some studies of antihypertensive drugs, with the aim of improving the estimate of 'true' resting BP values. In order to examine this claim, the variance of four sequential automatic recordings of BP and heart rate was evaluated in 66 subjects. The oscillometric Nippon Colin BP-103N sphygmomanometer has been previously shown by our group to give accurate and consistent measurements of BP. The means and medians of three sequential readings, by significantly decreasing the variability, were found to be superior to single measurements. The recorded mean arterial pressures were significantly higher than those calculated according to the current formula, on average by 3.6 mmHg, being situated between one third and one half of the distance between the systolic and diastolic pressures. The Page's rank test revealed that the first measurements were not uniformly the highest ones. Since the variability of the first to third BP values did not differ, medians of the three sequential recordings made at one minute intervals can be recommended as a standard BP characteristic.
More Related Videos
09:56Implantation of Combined Telemetric ECG and Blood Pressure Transmitters to Determine Spontaneous Baroreflex Sensitivity in Conscious Mice
Published on: February 14, 2021
14:28Software for Analysis of Heart Rate and Blood Pressure Time-series Data from the Valsalva Maneuver
Published on: June 27, 2025
Related Concept Videos
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Assessment of blood pressure in brachial artery(two-step method)
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Measurement of Blood Pressure