Related Experiment Video
Updated: Aug 18, 2026

Measurement of Tissue Oxygenation Using Near-Infrared Spectroscopy in Patients Undergoing Hemodialysis
Published on: October 2, 2020
Plasma endothelin-1 in hemodialysis treatment - the influence of hypertension
Ioannis Stefanidis1, Patrick Wurth, Peter Rene Mertens
1Division of Nephrology, University of Thessalia School of Medicine, Larissa, Greece. stefanid@med.uth.gr
In patients on chronic hemodialysis hypotensive episodes are frequently encountered during the course of treatment and the prevalence of atherosclerosis is increased. Endothelin-1 (ET-1), an endothelium-derived peptide with vasoconstrictive and mitogenic effects on smooth muscles, is involved in vascular tone regulation and in the pathogenesis of atherosclerosis. The aim of the present study was to investigate plasma ET-1 during hemodialysis treatment and to explore the probable influence of pre-existing hypertension. Forty-seven hemodialysis patients (21 females, mean age 62 +/- 12 years) were evaluated and hypertensive patients (n = 33) were compared to normotensive patients (n = 14). Relative blood volume changes (hemoglobinometry) and blood pressure were measured. Samples were taken before, every hour during and after hemodialysis. Plasma ET-1 was measured by enzyme-linked immunosorbent assay and results were corrected according to hemoconcentration. Hemodialysis with an ultrafiltration rate of 2224 +/- 933 mL was performed. Total blood volume at the end of hemodialysis was 89.4 +/- 8.2% of the pretreatment volume. The fall in blood pressure (137/74 +/- 22/11 mmHg vs 127/73 +/- 30/14 mmHg) correlated with the decrease in blood volume (mean blood pressure: r = 0.33). Plasma ET-1 increased from 1.29 +/- 0.47 pg/mL before to 1.46 +/- 0.56 pg/mL (reference range 0.3-0.9) at the end of hemodialysis (P < 0.05). This rise was more pronounced in patients with hypertension than in normotensive individuals (P < 0.05). The change in blood volume (r = 0.41) and blood pressure (mean blood pressure: r = 0.34) correlated with plasma ET-1 at the end of hemodialysis (P < 0.05). Plasma ET-1 was enhanced in hemodialysis patients compared to normal subjects. During the hemodialysis session an increase in ET-1 was encountered, which was more pronounced in hypertensive than in normotensive patients and paralleled the hemodynamic changes. Apart from pre-existing hypertension, further factors potentially influencing ET-1 include local endothelial injury (arteriovenous fistula) and generalized bioincompatibility reactions (e.g. foreign surface contact) occurring during hemodialysis.
In patients on chronic hemodialysis hypotensive episodes are frequently encountered during the course of treatment and the prevalence of atherosclerosis is increased. Endothelin-1 (ET-1), an endothelium-derived peptide with vasoconstrictive and mitogenic effects on smooth muscles, is involved in vascular tone regulation and in the pathogenesis of atherosclerosis. The aim of the present study was to investigate plasma ET-1 during hemodialysis treatment and to explore the probable influence of pre-existing hypertension. Forty-seven hemodialysis patients (21 females, mean age 62 +/- 12 years) were evaluated and hypertensive patients (n = 33) were compared to normotensive patients (n = 14). Relative blood volume changes (hemoglobinometry) and blood pressure were measured. Samples were taken before, every hour during and after hemodialysis. Plasma ET-1 was measured by enzyme-linked immunosorbent assay and results were corrected according to hemoconcentration. Hemodialysis with an ultrafiltration rate of 2224 +/- 933 mL was performed. Total blood volume at the end of hemodialysis was 89.4 +/- 8.2% of the pretreatment volume. The fall in blood pressure (137/74 +/- 22/11 mmHg vs 127/73 +/- 30/14 mmHg) correlated with the decrease in blood volume (mean blood pressure: r = 0.33). Plasma ET-1 increased from 1.29 +/- 0.47 pg/mL before to 1.46 +/- 0.56 pg/mL (reference range 0.3-0.9) at the end of hemodialysis (P < 0.05). This rise was more pronounced in patients with hypertension than in normotensive individuals (P < 0.05). The change in blood volume (r = 0.41) and blood pressure (mean blood pressure: r = 0.34) correlated with plasma ET-1 at the end of hemodialysis (P < 0.05). Plasma ET-1 was enhanced in hemodialysis patients compared to normal subjects. During the hemodialysis session an increase in ET-1 was encountered, which was more pronounced in hypertensive than in normotensive patients and paralleled the hemodynamic changes. Apart from pre-existing hypertension, further factors potentially influencing ET-1 include local endothelial injury (arteriovenous fistula) and generalized bioincompatibility reactions (e.g. foreign surface contact) occurring during hemodialysis.
Related Concept Videos
Hemodialysis I: Introduction
Hemodialysis III: Nursing Management
Hemodialysis II: Procedure and Complications
Treatment for Pulmonary Arterial Hypertension: Endothelin Receptor Antagonists
ETs are synthesized through a complex sequence of enzymatic steps, primarily involving an enzyme referred to as endothelin-converting enzyme (ECE). Of...
Dialysis
Acute kidney injury develops suddenly and can be caused by pre-renal causes (e.g., hypovolemia, shock), intrinsic renal causes (e.g., acute tubular necrosis), or post-renal causes (e.g., urinary obstruction). In contrast, chronic renal failure progresses gradually over time and is often...
Extracorporeal Removal of Drugs: Peritoneal Dialysis and Hemodialysis