Threshold modification for tumour imaging in non-small-cell lung cancer using positron emission tomography
Brian Yaremko1, Terence Riauka, Donald Robinson
1Department of Radiation Oncology, Cross Cancer Institute, Edmonton, Alberta, Canada.
Aim:
Positron emission tomography (PET) has been used increasingly in the staging and radiotherapy treatment planning of non-small-cell lung cancer (NSCLC). This study investigates the factors that affect the resultant size of a given image on PET.
Methods:
PET was used to assess the geometric characteristics of a series of radioisotope-filled, stationary spheres of known volume, surrounded by positron-emitting radioactive tracer of variable activity. The resultant PET-derived spherical volumes were then referenced to the known spherical volumes in order to illustrate quantitatively the potential influence of image threshold, tumour size and background concentration. This influence was further illustrated by clinical examples.
Results:
Considering the diameter of the spheres used in this study (10-48 mm), higher image thresholds were required for accurate rendering of the smallest spherical volumes. This inverse relationship was most consistently illustrated at the lowest background intensity ratios.
Conclusion:
PET-derived volumes of NSCLC must be interpreted with caution. The data presented in this study may be used to guide the selection of appropriate image thresholds for potential clinical application.
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET