Aims And Objectives:
To assess accuracy and reliability of two non-invasive methods, the chemical (Tempa.DOT) and tympanic thermometer (Genius First Temp M3000A), against the gold standard pulmonary artery catheter, and to determine the clinical significance of any temperature discrepancy using an expert panel.
Background:
There is continued debate surrounding the use of tympanic thermometry in clinical practice.
Design:
Prospective study.
Methods:
A total of 160 temperature sets were obtained from 25 adult intensive care patients over a 6-month period.
Results:
About 75.2% (n = 115) of chemical and 50.9% (n = 78) of tympanic readings were within a +/-0.0-0.4 degrees C range of the pulmonary artery catheter. Both the chemical and tympanic thermometers were significantly correlated with temperatures derived from the pulmonary artery catheter (r = 0.81, P < 0.0001 and r = 0.59, P < 0.0001) and limits of agreement were -0.5-0.9 degrees C and -1.2-1.2 degrees C respectively. The chemical thermometer was associated with a mean temperature difference of 0.2 degrees C, which increased 0.4 degrees C when used in conjunction with a warming blanket. With regard to clinical significance 15.3% (n = 26) of chemical and 21.1% (n = 35) of tympanic readings might have resulted in patients receiving delayed interventions. Conversely 28.8% (n = 44) of chemical and 37.8% (n = 58) of tympanic readings might have resulted in patients receiving unnecessary interventions.
Conclusions:
The chemical thermometer was more accurate, reliable and associated with fewer clinically significant temperature differences compared with the tympanic thermometer. However, compared with the pulmonary artery catheter both methods were associated with erroneous readings. In the light of these findings and previous research evidence, it is becoming increasingly difficult to defend the continued use of tympanic thermometry in clinical practice. However, as chemical thermometers are not without their limitations, further research needs to be undertaken to evaluate the accuracy and reliability of other non-invasive methods.
Relevance To Clinical Practice:
Chemical and tympanic thermometers are used in both adults and children in a wide variety of settings ranging from community to intensive care. As such these findings have significant implications for patients, users and budget holders.
More Related Videos
06:43Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...