Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Correlation of projection radiographs in radiation therapy using open curve segments and points
J M Balter1, C A Pelizzari, G T Chen
1Department of Radiation and Cellular Oncology, University of Chicago, Illinois 60637.
Abstract:
A method for determining differences in patient position between projection radiographs such as those routinely used in radiation therapy has been developed. Determination of a transformation relating two radiographs permits registration of simulation and portal images and the transfer of information between them. The algorithm is based on spatially registering segments of open curves or points seen on both images, and does not require identification of corresponding curve endpoints. The method as implemented is both fast and accurate. After user definition of the curves or points to be registered, the optimal transformation is calculated in approximately 1 s. Calculational experiments indicate that corresponding points on open curves are registered to better than 2 mm, even when random errors (FWHM 1 mm) in digitization are included. Experiments on the registration of clinical portal and simulation images (pixel size = 0.5 by 0.5 mm) indicate an accuracy on the order of 2 mm or less in translation and 2 deg or less in rotation. Analysis of portal and simulation radiographs of the brain, thorax, and pelvis indicates this algorithm to be robust and clinically applicable. The rapid and accurate registration of portal and simulation images is potentially important in the application of real time portal imaging devices in radiation therapy.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
05:18Radiation Planning Assistant - A Web-based Tool to Support High-quality Radiotherapy in Clinics with Limited Resources
Published on: October 6, 2023
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body being...
Radiological Investigation I: X-ray and CT