Related Experiment Video
Updated: Aug 18, 2026

Esophageal Heat Transfer for Patient Temperature Control and Targeted Temperature Management
Published on: November 21, 2017
Diagnostic accuracy of routine postoperative body temperature measurements
Hester Vermeulen1, Marja N Storm-Versloot, Astrid Goossens
1Department of Surgery, Academic Medical Center, University of Amsterdam, Amsterdam, The Netherlands.
Background:
On surgical wards, body temperature is routinely measured, but there is no proof that this is useful for detecting postoperative infection. The aim of this study was to compare temperature measurements (the test) with the confirmed absence or presence of a postoperative infection (the reference standard).
Methods:
A prospective triple-blinded diagnostic study involving 308 consecutive patients was performed. A positive test result was defined as a postoperative temperature > or = 38.0 degrees C. The reference standard was considered to indicate a postoperative infection if results of a bacterial culture were positive or if an infection was suspected on clinical grounds.
Results:
Data for 284 of 308 patients were analyzed (2282 temperature measurements). The prevalence of infection was 7% (19 of 284 patients). The temperature curves of patients were used as units of analysis and revealed that a temperature > or = 38.0 degrees C had a sensitivity of 37% (95% confidence interval [CI], 0.16%-0.62%) and a specificity of 80% (95% CI, 0.75%-0.85%). The likelihood ratio for a positive test result was 1.8 (95% CI, 0.7-4.0) and for a negative test result was 0.8 (95% CI, 0.4-1.4). When all 2282 measurements were considered as independent test results, the positive predictive value was only 8% (95% CI, 5%-13%). Six of 8 patients with a severe infection had temperatures < 38 degrees C.
Conclusion:
Routine measurement of body temperature is of limited value in the detection of infection after elective surgery for noninfectious conditions. Serious postoperative infections can even occur without an accompanying increase in temperature.
Related Concept Videos
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...