Operational options to reduce matrix effects in liquid chromatography-electrospray ionization-mass spectrometry
Achim Kloepfer1, José Benito Quintana, Thorsten Reemtsma
1Department of Water Quality Control, Technical University of Berlin, 10623 Berlin, Germany.
Abstract:
Matrix effects like signal enhancement or suppression can severely compromise quantitative analysis of environmental samples with liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS). Several operational options were studied to reduce such matrix effects in the determination of polar organic trace contaminants from water, like non-steroidal anti-inflammatory drugs, among them ibuprofen, diclofenac and naproxen, lipid regulators like bezafibrate and clofibric acid and industrial chemicals (2-substituted benzothiazoles). A step-wise removal of organic matrix from a wastewater sample by ultrafiltration showed that the majority of matrix effects in that sample was due to low molecular weight compounds <1 kDa. For such wastewaters samples size-exclusion, as in restricted access material (RAM), is not a useful clean-up strategy. Reducing the eluent flow entering the ESI interface by post-column splitting increased instrumental sensitivity and reduced matrix effects. The flow optimum was analyte-dependent and ranged from 20 to 100 microL/min. Sensitivity in the positive ion mode increased up to nine-fold upon flow-reduction for some analytes detected in the positive ion mode. At low flow rates matrix effects are reduced by 45-60% on average. If moderate matrix effects occurred, post-column splitting may allow obtaining reliable quantitative data even with external calibration.
More Related Videos
07:12An Efficient Sample Preparation Method to Enhance Carbohydrate Ion Signals in Matrix-assisted Laser Desorption/Ionization Mass Spectrometry
Published on: July 29, 2018
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
MALDI-TOF Mass Spectrometry
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
High-Performance Liquid Chromatography: Types of Detectors
Matrix-Assisted Laser Desorption Ionization (MALDI)