Comprehensive two-dimensional gas chromatography coupled to a rapid-scanning quadrupole mass spectrometer: principles
Mohamed Adahchour1, Menno Brandt, Hans-Ulrich Baier
1Department of Analytical Chemistry and Applied Spectroscopy, Vrije Universiteit, de Boelelaan 1083, 1081 HV Amsterdam, The Netherlands. m.adahchour@few.vu.nl
Abstract:
The principles, practicability and potential of comprehensive two-dimensional (2D) gas chromatography coupled to a rapid-scanning quadrupole mass spectrometer (GC x GC-qMS) for the analysis of complex flavour mixtures in food, allergens in fragrances and polychlorinated biphenyls (PCBs) were studied. With a scan speed of 10,000 amu/s, monitoring over a mass range of up to 200 atomic mass unit (amu) can be achieved at an acquisition frequency of 33 Hz. Extending this mass range and/or increasing the data acquisition frequency results in a loss of spectral quality. Optimal parameter settings allow, next to unambiguous identification/confirmation of target compounds on the basis of high-quality mass spectra, fully satisfactory quantification (three to four modulations per peak) with linear calibration plots and detection limits in the low-pg level. The potential of time-scheduled data acquisition to increase the effective mass range within one GC x GC run was also explored. The analyses, with baseline separation of the flavours, allergens and PCB target compounds, took less than 30 min.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Analyzers: Common Types
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
