Related Experiment Video
Updated: Aug 10, 2026

Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Quadrupole mass spectrometer operating in the electron-capture negative ion mode as detector for comprehensive
P Korytár1, J Parera, P E G Leonards
1Netherlands Institute for Fisheries Research, 1970 AB IJmuiden, The Netherlands. peter.korytar@wur.nl
Abstract:
A recently introduced rapid-scanning quadrupole mass spectrometer (qMS) with an electron-capture negative ion (ECNI) option, the Perkin-Elmer Clarus 500, was tested as a detector for comprehensive two-dimensional gas chromatography (GC x GC). The parameters influencing the data acquisition rate in the scan mode, such as scan time and inter-scan delay, and in the selected ion monitoring mode, such as dwell time and inter-channel delay, were evaluated. In the scan mode, good-quality mass spectra covering a range of 300 Da can be obtained at an acquisition rate of 23 Hz; in selected ion monitoring, an acquisition rate of 90Hz can be achieved when monitoring a single ion. Compared with electron ionisation, the use of electron-capture negative ionisation causes no extra peak broadening. As applications, mixtures of polychlorinated n-alkanes (PCAs), polybrominated diphenyl ethers (PBDEs) and polychlorinated dibenzo-p-dioxins (PCDDs) and dibenzofurans (PCDFs) were analysed. The separation of PCAs based on their number of chlorine substituents was confirmed for the first time by using GC x GC-ECNI qMS in the scan mode and a significantly improved limit of detection was achieved for BDEs (10-150 fg injected) and CDD/Fs (10-700 fg injected) in the selected ion monitoring mode.
More Related Videos
07:53Analysis of Complex Molecules and Their Reactions on Surfaces by Means of Cluster-Induced Desorption/Ionization Mass Spectrometry
Published on: March 1, 2020
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Related Concept Videos
Mass Spectrometers
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Analyzers: Common Types
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Tandem Mass Spectrometry
Gas Chromatography: Types of Detectors-II