Towards smaller and faster gas chromatography-mass spectrometry systems for field chemical detection
P A Smith1, M T Sng, B A Eckenrode
1Naval Medical Center San Diego, Industrial Hygiene Department, San Diego, CA, USA. pasmith@nmcsd.med.navy.mil
Abstract:
Gas chromatography-mass spectrometry (GC-MS) is already an important laboratory method, but new sampling techniques and column heating approaches will expand and improve its usefulness for detection and identification of unknown chemicals in field settings. In order to demonstrate commercially-available technical advances for both sampling and column heating, we used solid phase microextraction (SPME) sampling of both water and air systems, followed by immediate analysis with a resistively heated analytical column and mass spectrometric detection. High-concern compounds ranging from 140 to 466 amu were analyzed to show the applicability of these techniques to emergency situations impacting public health. A field portable (about 35 kg) GC-MS system was used for analysis of water samples with a resistively heated analytical column externally mounted as a retrofit using the air bath oven of the original instrument design to heat transfer lines. The system used to analyze air samples included a laboratory mass spectrometer with a dedicated resistive column heating arrangement (no legacy air bath column oven). The combined sampling and analysis time was less than 10 min for both air and water sample types. By combining dedicated resistive column heating with smaller mass spectrometry systems designed specificallyfor use in the field, substantially smaller high performance field-portable instrumentation will be possible.
More Related Videos
10:14Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
05:31Gas Chromatography-Mass Spectrometry Paired with Total Vaporization Solid-Phase Microextraction as a Forensic Tool
Published on: May 25, 2021
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Types of Detectors-II
High-Performance Liquid Chromatography: Types of Detectors