Related Experiment Video
Updated: Aug 1, 2026

How to Administer Near-Infrared Spectroscopy in Critically ill Neonates, Infants, and Children
Published on: August 19, 2020
[False low oximetry reading caused by patent blue vital dye during breast surgery]
L A Nasif1, J M Campos, S Piñol
1Servicio de Anestesiología, Reanimación y Terapéutica del Dolor del Hospital de la Santa Creu i Sant Pau, Barcelona.
Abstract:
Patent blue vital (patent blue V; Laboratoire Guerbet, France) is used to identify the sentinel node during surgery for invasive breast cancer. Detecting the sentinel node that first drains the primary tumor reduces the need for total breast and wide axillary node removal, with the problems that such radical surgery involves. Like other dyes, patent blue V can interfere with accurate pulse oximeter reading, leading to underestimation of real values. We report the case of a 31-year-old woman who underwent lumpectomy and removal of the sentinel node. After intradermal injection of patent blue V dye into the left breast (100 mg administered because the sentinel node was difficult to locate) a drop in peripheral oxyhemoglobin saturation from 99% to 93% was detected by the pulse oximeter. When arterial blood gas analysis showed normal values and other causes were ruled out, the diagnosis was false low oximetry reading due to patent blue V dye.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
04:44Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
Published on: March 22, 2024
Related Concept Videos
Guidelines For Measuring Vital Signs
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...