Related Experiment Video
Updated: Aug 18, 2026

Analysis of AtHIRD11 Intrinsic Disorder and Binding Towards Metal Ions by Capillary Gel Electrophoresis and Affinity Capillary Electrophoresis
Published on: August 22, 2018
Simultaneous detection of [metal(II)-tpen]2+ as kinetically inert cationic complexes using pre-capillary
Shingo Saito1, Satoru Sasamura, Suwaru Hoshi
1Department of Applied and Environmental Chemistry, Kitami Institute of Technology, 165 Koen-cho, Kitami, Hokkaido 090-8507, Japan. shingo@serv.chem.kitami-it.ac.jp
Abstract:
A high resolution of doubly charged first row transition (Fe, Cu, Zn, Ni, Co, Mn) and heavy metal (Pb, Cd, Hg) ions was achieved in capillary electrophoresis (CE) with high sensitivity (sub-micromol dm(-3) level), using NN,N'N'-tetrakis(2-pyridylmethyl)ethylenediamine (TPEN) as a pre-capillary derivatizing agent. The non-charged reagent, TPEN, was applied to capillary zone electrophoresis (CZE) for the first time. Since complete spatial separation between the complexes and the ligand was carried out in a carrier buffer, which was free of TPEN, kinetic inertness of metal complexes was necessary for the detection in this pre-capillary method. All the nine listed metal complexes were detected: Ca(2+), Mg(2+), Al(3+), Fe(3+), and Co(3+) complexes were undetectable. This, interestingly, suggests that those nine cations form kinetically inert tpen complexes without strong charge-charge interactions between the metal ion and the ligand. It is expected that the hard-soft-acid-base (HSAB) principle governed the kinetics selectivity. With respect to the electrophoretic behavior, the addition of chloride ion and methanol to the carrier significantly improved the resolution. This is due to the formation of ternary complexes or ion aggregates and the solvation effect, respectively. These effects provided a satisfactory baseline resolution among the nine metal ions. An application to biological samples was demonstrated. Some metal ions in human serum and urine were successfully detected in a simple process without the need for deproteinization using a non-coated fused-silica capillary because of the differenciation in the direction of migration between organic matter and complexes.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Extraction: Advanced Methods
Capillary Electrophoresis: Instrumentation
Electrophoresis: Overview
There...
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on the metal...

