Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
Flexural properties of eight flowable light-cured restorative materials, in immediate vs 24-hour water storage
Rosalina Tjandrawinata1, Masao Irie, Kazuomi Suzuki
1Department of Biomaterials, Okayama University Graduate School of Medicine and Dentistry, Okayama, Japan.
Abstract:
This study evaluated the flexural strength, flexural modulus, modulus of resilience and water sorption of eight flowable light-cured restorative materials compared with two conventional restoratives (as control). Forty specimens of each material were made. Twenty specimens were immediately flexural tested, while the remaining 20 were weight-measured and immersed in distilled water in a 37 degrees C incubator. After 24 hours, the samples were weight-measured again to identify water sorption and they were flexural tested. The findings were statistically analyzed using t-test, one-way ANOVA, Tukey test and Pearson's Product-Moment Correlation. The results of the flexural strength test were also analyzed using Weibull statistic. All flowable light-cured restorative materials except Palfique Estelite Low Flow exhibited immediate flexural strength values between the conventional ones. All flowable light-cured restorative materials showed 24-hour flexural strength values between the conventional ones. The Weibull modulus for immediate flexural strength of the materials varied from 6.37 to 15.23, while for 24-hour flexural strength, the strength varied from 8.10 to 14.30. In both conditions, all flowable light-cured resin composites showed lower flexural moduli but higher modulus of resilience than the conventional ones. The water sorption of all resin composites was lower than the flowable light-cured compomer. There was a distinct relation (r=-0.84, p<0.01) between the increasing ratio in modulus of resilience and the amount of water sorption.
Related Concept Videos
Testing Water Quality
Mortar Properties
Curing of Concrete
Flow Table Test
Concrete is placed within a truncated cone mold that is 8 inches high with an 8-inch base diameter and a 5-inch top diameter. The...
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in ASTM C...
Porosity in Cement Paste
The balance of water to cement in the mix is critical—it...