Related Experiment Video
Updated: Aug 18, 2026

Surgical Porcine Model of Chronic Myocardial Ischemia Treated by Exosome-laden Collagen Patch and Off-pump Coronary Artery Bypass Graft
Published on: September 15, 2023
"Off-pump" repair of a postangioplasty coronary artery bleed
Luke R Devey1, Thomas R D Shaw, Vipin Zamvar
1Department of Cardiothoracic Surgery, Royal Infirmary of Edinburgh, Little France Crescent, Edinburgh. devey@doctors.org.uk
Insights
A patient experienced cardiac tamponade after coronary stenting. Off-pump surgical techniques were successfully used to repair a leaking coronary artery, demonstrating their expanding role beyond bypass surgery.
Area of Science:
- Cardiovascular Surgery
- Interventional Cardiology
Background:
- Percutaneous coronary intervention (PCI) with stenting is a common procedure for coronary artery disease.
- Complications such as cardiac tamponade can occur despite successful stenting.
- Anticoagulation therapy increases the risk of bleeding complications post-PCI.
Observation:
- A 65-year-old man developed cardiac tamponade and arrest following multivessel coronary stenting and anticoagulation.
- Repeat angiography revealed contrast extravasation from a circumflex artery subbranch.
- The patient required intervention for the bleeding coronary vessel.
Findings:
- The leaking coronary artery subbranch was successfully oversewn using the Medtronic Octopus Retractor.
- This surgical repair was performed using an off-pump technique.
- The procedure was completed with reduced procedural time and morbidity compared to on-pump methods.
Implications:
- This case highlights the successful application of off-pump techniques for managing complications of percutaneous coronary intervention.
- It demonstrates the versatility of off-pump stabilization systems beyond traditional coronary artery bypass grafting.
- The findings suggest that off-pump strategies may offer a less morbid alternative for specific post-PCI bleeding complications.
Abstract:
Following percutaneous multivessel coronary stent implantation with full anticoagulation, a 65-year-old man suffered tamponade and cardiac arrest. After successful resuscitation, he underwent repeat coronary angiography which demonstrated extravasation of contrast from a distal circumflex subbranch. Thereafter, he was transferred to the cardiothoracic surgery unit where the leaking vessel was oversewn using the Medtronic Octopus Retractor for stabilization. This report illustrates the growing wider use of "off-pump" techniques beyond coronary artery bypass grafting. In this case, the patient was exposed to a much shorter procedure with less morbidity than could have been expected had cardiopulmonary bypass been used.
More Related Videos
14:35Post-Myocardial Infarction Heart Failure in Closed-chest Coronary Occlusion/Reperfusion Model in Göttingen Minipigs and Landrace Pigs
Published on: April 17, 2021
12:00Evaluation of a Novel Laser-assisted Coronary Anastomotic Connector - the Trinity Clip - in a Porcine Off-pump Bypass Model
Published on: November 24, 2014
Related Concept Videos
Aneurysm III: Interprofessional Care
Peripheral Artery Disease V: Postoperative Nursing Management
Peripheral Artery Disease III: Interprofessional Care