[Evaluation of image quality of the Iso C3D image processor in comparison to computer tomography. Use in the pelvic
B König1, U Erdmenger, R J Schröder
1Zentrum für Muskuloskeletale Chirurgie, Klinik für Unfall- und Wiederherstellungschirurgie der CHARITE-Universitätsmedizin Berlin, Campus Virchow-Klinikum, Berlin. benjamin.koenig@charite.de
Abstract:
Intraoperative 3-D visualization using the Siremobil Iso C(3D) (Siemens, Erlangen, Germany) has been approved for use in spine and long bone surgery since its recent clinical launch. In preparation for the clinical use of the Siremobil Iso C(3D) in pelvic surgery, the aim of this study was to grade the quality of visualization in comparison with the gold standard of computer tomography in four therapy relevant pelvic regions in eight human cadavers, including SI screws to exemplify implants in the dorsal pelvic ring. Besides the influence of the body mass index and the interference of metal artefacts, visualization quality was evaluated in different pelvic regions (sacroiliac joint, acetabulum, femoral neck and anterior pelvic ring) using a score with five subgroups, rating the applicability of Siremobil Iso C(3D) in pelvic surgery. The grading of image quality in comparable standard projections was performed independently by three surgeons and three radiologists.Visualization quality appeared sufficient for both intraoperative and postoperative control in cases with a known preoperative diagnosis. There was no influence of body mass index found in any of the eight cadavers. Implants positioned in the dorsal pelvic ring reduced visualization quality, but sufficient estimation of bony structures was still possible. For primary diagnostics, computer tomography remains a clearly superior option due to better image quality. For intraoperative control of the reduction and positioning of implants in pelvic surgery, however, the additional intraoperative use of Siremobil Iso C(3D) is considered to offer clear advantages over current 2-D C-arm visualization tools.
More Related Videos
12:32Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies IV: Magnetic Resonance Imaging
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and solid...