An X-ray microscopy perspective on the effect of glutaraldehyde fixation on cells
S Jearanaikoon1, J V Abraham-Peskir
1Institute for Storage Ring Facilities (ISA), Department of Physics and Astronomy, University of Aarhus, Ny Munkegade, DK-8000 Aarhus C, Denmark. jearanai@phys.au.dk
Abstract:
X-ray microscopy (XRM) is the only microscopy technique that can provide high-resolution (30 nm) imaging of biological specimens without the need to fix, stain or section them. We aim to determine the effect, if any, of glutaraldehyde fixation on algae cells from the XRM perspective and thus provide beneficial information for both X-ray and electron microscopists on artefacts induced by glutaraldehyde fixation. Three species of microalgae, Microcystis aeruginosa, Anabaena spiroides and Chlorella vulgaris, were used in this study. XRM images were obtained from unfixed and glutaraldehyde-fixed cells and cell diameter and percentage X-ray absorbency were measured. The mean diameter of cells from fixed preparations was smaller than from unfixed preparations; the mean diameter of M. aeruginosa cells was significantly reduced from 3.92 microm in unfixed cells to 3.43 microm in fixed cells (P < 0.05); in C. vulgaris the diameter of cells was also significantly reduced from 3.50 microm in unfixed to 2.98 microm in fixed samples (P < 0.05); whereas there was no significant reduction in the diameter of A. spiroides cells (4.04-3.90 microm). The protein crosslinking mechanism of glutaraldehyde probably generated free water molecules, which play an important role in radiation damage induced by X-rays. This was seen as mass loss and cell shrinkage, which in the present study occurred more frequently in fixed cells than in unfixed cells. In addition, we demonstrated that the uptake of glutaraldehyde by cells makes all protein constituents in the cell organize into a closely packed configuration, thus causing a rise in the percentage of X-ray absorbency. In fixed cells, this rise was approximately by a factor of two compared with unfixed samples in which protein constituents inside the cell are arranged in their native form.
Related Concept Videos
Preparation of Samples for Electron Microscopy
Fixation and Sectioning
The simplest type of preparation is the wet mount, in which the specimen is placed in a drop of liquid on the slide. A liquid specimen can be directly deposited on the slide using a dropper. Solid specimens, such as skin scraping, can be placed on the slide before adding a drop of liquid to prepare the wet mount. Sometimes the liquid is simply water, but stains are often added...
Simple Staining Technique
Cryo-electron Microscopy