Abstract:
An equivalent circuit model is put forward through analysis of the experiment data under the conditions of applying 400V, 350V and 300V DC supply power to a small-scale simulated landfill. Due to the fact that the existence of the HDPE geomembrane liner endows the model with commutating character, the electrolytic capacity increases as the area of geomembrane liner and the supplying electric voltage increase. The contact electric resistance of the power supply electrode is in direct proportion to earth electric resistance rate, and in relation to the diameter of the electrode and the depth of the earth. Moreover, the contact resistance is mainly determined by the earth electric resistance around the electrode (the influence induced by the earth farther than 10 times electrode radius is less than 10 percent of those involved by all resistance), hence decrease of the earth electric resistance rate around the electrode may result in effective decrease of the contact electric resistance of the electrode.
Related Concept Videos
Series R—L Circuit Transients
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists of...
Power System Three-Phase Short Circuits
Parallel RLC Circuits
A simplified parallel RLC circuit model with a DC input source generating a step response is employed in this context. When the switch is turned on, Kirchhoff's current law is applied, leading to a second-order differential equation.
Equivalent Circuits for Practical Transformers
In a practical transformer, each winding exhibits resistance and leakage reactance. The winding...
RL Circuit without Source
Applying Kirchhoff's voltage law around the loop of the circuit and substituting the voltages across the inductor and resistor yields a first-order differential equation. A logarithmic equation is obtained by rearranging the terms in this equation, integrating...
Series RLC Circuit with Source
In this context, the input DC voltage serves as a forcing step function, resulting in a forced step response that mirrors the characteristics of the input. Applying Kirchhoff's voltage law to the circuit yields a...