Related Experiment Video
Updated: Aug 18, 2026

Amikacin Protection Assay for Quantification and Visualization of Escherichia coli Cell Invasion
Published on: July 3, 2026
Endotoxin-like reactions with intravenous gentamicin: results from pharmacovigilance tools under investigation
1Risk Management Strategy, Pfizer Inc., New York, New York 10017, USA.
Objective:
To apply two data mining algorithms (DMAs) to Food and Drug Administration (FDA) Adverse Event Reporting System (AERS) reports that involved endotoxin-like reactions with intravenous gentamicin to determine whether a signal of disproportionate reporting of these events would have been generated concurrently with surveillance based on clinical observation.
Design:
Multi-item gamma-Poisson shrinker (MGPS) and proportional reporting ratios (PRRs) were used. Data used for data mining consisted of an extract of the FDA AERS database. Previously published details of clusters of endotoxin-like reactions to intravenous gentamicin were used to select adverse events for data mining.
Results:
The first signal of disproportionate reporting with any relevant event occurred in 1998, the year in which the outbreak was identified and evaluated by the Centers for Disease Control and Prevention and the FDA. In 1997, there were only 6 reports of rigors in the AERS; this jumped to 68 in 1998. In 1998, a signal was generated for endotoxic shock with PRRs but not with MGPS, based on one case.
Conclusions:
The two DMAs generated signals concurrently with the influx of reports. It would have been difficult for safety reviewers to ignore an increase in rigors by traditional methods of safety surveillance; therefore, DMAs might not have had a great deal to offer in this instance. If data mining were considered as a second-line defense to diligent clinical observations under similar circumstances, simple disproportionality methods such as PRRs might be more useful than DMAs such as MGPS when commonly cited thresholds are used.
Related Concept Videos
Determination of Multiple Dosing Parameters: Steady-State, Minimum and Maximum Concentrations
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Automated Microbial Diagnostics
Mechanism of Antibiotic Resistance in MRSA
Botulism