Ultraviolet fluorescence spectra of fingerprints
Naoki Saitoh1, Norimitsu Akiba
1Second Forensic Science Division, National Research Institute of Police Science, 6-3-1 Kashiwanoha, Kashiwa, Chiba 277-0882, Japan. saitohn@nrips.go.jp
Abstract:
We have studied inherent fluorescence spectra and imaging of fingerprints in the deep ultraviolet (UV) region with a nanosecond-pulsed Nd-YAG laser system that consists of a tunable laser, a cooled CCD camera, and a grating spectrometer. In this paper, we have studied UV fluorescence spectra of fingerprints under 266-nm illumination. Fluorescence spectra of fingerprints have two main peaks, around 330 nm (peak A) and 440 nm (peak B). At first, when a fingerprint has just been pressed, peak A is dominant. However, its intensity reduces as the total illumination time increases. On the other hand, peak B is weak at first. It appears after enough 266-nm illumination and its intensity increases as time elapses. After 3 h of illumination, peak A almost diminishes and peak B becomes dominant. By leaving the fingerprint under a fluorescent lamp in a room without laser illumination, peak A can be restored partly, while the intensity of peak B still increases. Time-resolved fluorescence spectra were also measured for these two peaks. The lifetime of each peak is 2.0 nsec (peak A) and 6.2 nsec (peak B) on average. Both peaks seem to consist of several components with different lifetimes. In the case of peak A, the 330-nm peak decays fast and a new component at 360 nm becomes dominant when the delay time exceeds 20 nsec. In the case of peak B, unlike peak A, no clear peak separation is observed, but the peak position seems to move from 440 to 460 nm when the delay time becomes larger.
More Related Videos
09:50Enhanced Photoluminescence of Curcuma longa Extracts via Chitosan-Mediated Energy Transfer for Textile Authentication Applications
Published on: December 22, 2023
09:59Laser-free Hydroxyl Radical Protein Footprinting to Perform Higher Order Structural Analysis of Proteins
Published on: June 4, 2021
Related Concept Videos
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
IR Frequency Region: Fingerprint Region
The...
UV–Vis Spectrometers
UV–Vis Spectrum
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...
UV–Vis Spectroscopy: Molecular Electronic Transitions
IR and UV–Vis Spectroscopy of Aldehydes and Ketones