Spectrophotometric determination of ferrate (Fe(VI)) in water by ABTS
Yunho Lee1, Jeyong Yoon, Urs von Gunten
1School of Chemical and Biological Engineering, College of Engineering, Seoul National University, San 56-1, Sillim-dong, Gwanak-gu, Seoul 151-742, Korea.
Abstract:
A new method for the determination of low concentrations (0.03-35 microM) of the aqueous ferrate (Fe(VI)) was developed. The method is based on the reaction of Fe(VI) with 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonate) (ABTS) which forms a green radical cation (ABTS(+)) that can be measured spectrophotometrically at 415 nm (ABTS method). The reaction of Fe(VI) with ABTS has a stoichiometry of 1 : 1 in excess of ABTS (73 microM). The increase in absorbance at 415 nm for ABTS*+ generation was linear with respect to Fe(VI) added (0.03-35 microM) in buffered solutions (acetate/phosphate buffer at pH = 4.3) and was (3.40+/-0.05) x 10(4) M(-1) cm(-1). The reaction of Fe(VI) with ABTS was very rapid with a half-life time below 0.01 s at pH 4.3 and 73 microM of ABTS. This enables the ABTS method to measure Fe(VI) selectively. The residual absorbance of ABTS*+ was found to be stable in several water matrices (synthetic buffer solution and natural waters) and concentrations of Fe(VI) spiked in natural waters could be determined with high accuracy. The ABTS method can also be used as a tool to determine rate constants of reactions of Fe(VI). The second-order rate constant for the reaction of phenol with Fe(VI) was determined to be 90 M(-1) s(-1) at pH 7.
Related Concept Videos
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Atomic Fluorescence Spectroscopy
Spectrophotometry: Introduction
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing nebulizer...
Precipitation and Co-precipitation


