Related Experiment Video
Updated: Aug 18, 2026

Humanized Mediator Release Assay as a Read-Out for Allergen Potency
Published on: June 29, 2021
Hypertonicity of the challenge solution may increase the diagnostic accuracy of histamine challenge
Heikki O Koskela1, Kirsi M Kontra, Minna K Purokivi
1Department of Respiratory Medicine, Kuopio University Hospital, P.O. Box 1777, Kuopio 70211, Finland. heikki.koskela@kuh.fi
Abstract:
There is significant overlap in the responsiveness to direct airway challenges, such as the histamine challenge, between asthmatic and non-asthmatic subjects, which decreases their accuracy in the diagnosis of asthma. To minimise this overlap, a new test, hypertonic histamine challenge, was developed. Fifteen healthy subjects, 16 subjects with steroid-naive asthma, and 16 asthmatic subjects undergoing inhaled corticosteroid treatment underwent inhalation challenges with hypertonic saline, isotonic histamine, and hypertonic histamine, using an ultrasonic nebuliser and 2-min tidal breathing method. The increase in histamine solution tonicity decreased the histamine PC20 values only in the steroid-naive asthmatic subjects (1.1 (0.5-2.7) vs. 0.5 (0.2-1.2) mg/ml, P = 0.047). Using 1mg/ml as the cut-off value, the sensitivity, specificity, and accuracy of the hypertonic histamine challenge to detect steroid-naive asthma was 81%, 100%, and 90%. The respective values for the isotonic histamine challenge were 56%, 100%, and 77%. Furthermore, there was a statistically significant difference in the hypertonic histamine PC20 between steroid-naive and steroid-treated asthmatic subjects, which could not be detected in the isotonic histamine PC20. The hypertonic histamine PC20 was highly repeatable, with a single determination 95% range of +/-1.35 doubling concentrations. The hypertonic histamine challenge was safe but provoked more cough and throat irritation than the other two challenges. In conclusion, compared with a conventional, isotonic histamine challenge, hypertonic histamine challenge may be more accurate in the diagnosis of asthma and also, more capable to detect the effects of inhaled corticosteroid treatment.
Related Concept Videos
Tonicity in Animals
Drug Toxicity: Allergic Reactions
Allergic Reactions: Anaphylaxis
Titration of a Weak Base with a Strong Acid
Using the ICE table and substituting the Kb value, we calculate the initial pH of 50 mL of 0.1 M ammonia to be 11.11. Addition of 25 mL of 0.1 M hydrochloric acid to this solution of ammonia results in a buffer with an equal concentration of ammonia and ammonium ions. The pH of this buffer can be calculated by substituting these...
Henderson-Hasselbalch Equation