Related Experiment Video
Updated: Feb 11, 2026

Automatic Laser-based Geometry Capture for Finite Element Analysis of Weld Beads
Published on: July 25, 2025
Active site identification through geometry-based and sequence profile-based calculations: burial of catalytic clefts
Richard Greaves1, Jim Warwicker
1Faculty of Life Sciences, Jackson's Mill, University of Manchester, P.O. Box 88, Sackville Street, Manchester M60 1QD, UK.
Abstract:
Electrostatics calculations with proteins that are uniformly charged over volume can aid enzyme/non-enzyme discrimination. For known enzymes, such methods locate active sites to within 5% on the enzyme surface, in 77% of a test set. We now report that removing the dielectric boundary improves active site location to 80%, with optimal discrimination between enzymes and non-enzymes of around 80% specificity and 80% sensitivity. This calculation quantifies burial of solvent-accessible regions. Many of the true enzymes incorrectly assigned as non-enzymes have active sites at subunit boundaries. These are missed in monomer-based calculations. Catalytic and non-catalytic antibodies are studied in this context of active/binding site burial. Whilst catalytic antibodies, on average, have marginally higher active site burial than non-catalytic antibodies, these values are generally smaller than for non-antibody enzymes, possibly contributing to their relatively low turnover. Prediction of active site location improves further when sequence profile-based weights replace the uniform charge distribution, so that a combination of burial and amino acid conservation is assessed. Accuracy rises to 93% of active sites to within 5%, in the test set, for the optimal profile weights scheme. The equivalent value in a separate validation set is 89% to within 5%. Enzyme/non-enzyme and enzyme functional site predictions are made for structural genomics proteins, suggesting that a substantial majority of these are non-enzymes.
Related Concept Videos
Geometry of Hyperbolas
Titration Calculations: Weak Acid - Strong Base
For the titration of 25.00 mL of 0.100 M CH3CO2H with 0.100 M NaOH, the reaction can be represented as:
Titration Calculations: Strong Acid - Strong Base
A titration is carried out for 25.00 mL of 0.100 M HCl (strong acid) with 0.100 M of a strong base NaOH. The pH at different volumes of added base solution can be calculated as follows:
(a) Titrant volume = 0 mL. The solution pH is due to the acid ionization of HCl. Because this is a strong acid, the ionization is complete and the hydronium ion molarity is 0.100 M. The pH of the solution is then:
Coordination Number and Geometry
Acid–Base Equilibria: Activity-Based Definition of pH
In solutions of very low ionic strength—for example, pure water—the...
Predicting Molecular Geometry

