Comparison of CIE lab, CIEDE 2000, and DIN 99 color differences between various shades of resin composites
1Department of Dental Biomaterials Science, College of Dentistry, Seoul National University, Korea. ykleedm@snu.ac.kr
Purpose:
In addition to the CIE Lab color-difference formula (deltaE*ab), advanced formulas that include weighting functions have been introduced. The objectives of this study were to determine the correlations in color differences between different shade pairs of resin composites by different color formulas, and to determine whether the weighting functions included in the advanced formulas influenced the color-difference values.
Materials And Methods:
Color was measured after polymerization of two resin composites in 26 shades, and color differences between shades were calculated by deltaE*ab, CIEDE 2000 (deltaE00), and DIN 99 (deltaE99) formulas. Regression analyses were performed between the color differences calculated by three formulas in each group divided by the differences in color parametric factors between the pairs compared.
Results:
There were significant correlations between deltaEab and deltaE00, deltaEab and deltaE99, and deltaE99 and deltaE00 (r2 = .99, .89, and .90, respectively). The weighting functions in the CIEDE 2000 formula had influence on deltaE00 values when differences in chroma and hue between compared pairs were great.
Conclusion:
Differences in parametric factors between the pairs compared influenced the correlation between deltaE*ab and deltaE99 values (r2 = .25 to .97). As the CIEDE 2000 formula has been proven to be better matched to observer responses and showed significant involvement of weighting functions compared to CIE Lab color difference, this formula should be considered for evaluation of the color of resin composites.
Related Concept Videos
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a result, EDTA...
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...