Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures
1Department of Trauma Surgery and Sports Medicine, Medical University Innsbruck (MUI), Anichstrasse 35, 6020 , Innsbruck, Austria. rohit.arora@uibk.ac.at
Introduction:
This study investigates the clinical and radiological results of open reduction and internal fixation of unstable distal radial fractures using a palmar placed interlocking plate system with no substitutes for treatment of the dorsal metaphyseal fracture void.
Materials And Methods:
Nineteen patients with a mean age of 61 years (range 49-78 years) and a dorsally displaced distal radial fracture were treated using a palmar placed 2.4 mm interlocking plate system. All 17 women and 2 men were followed up according to the study protocol. Standardised radiographs in anteroposterior and lateral projection were performed before reduction and at 2, 6, 12 and 24 weeks after surgery. Radiological measurements included palmar tilt, radial inclination and radial shortening as defined by ulnar variance and intra-articular steps. Clinical assessment included active range of motion (ARM) of the wrist, pain according to a visual analogue scale (VAS), grip power, working ability, Disability of Arm, Shoulder and Hand-Score (DASH Score) and Mayo Wrist Score.
Results:
At final follow-up after a minimum of 11 months, the palmar tilt was +1 degrees , radial inclination 19.8 degrees and ulnar variance 1.0 mm. Mean loss of palmar tilt measured 1.9 degrees , radial inclination 1.3 degrees and ulnar variance 0.4 mm. Mean wrist extension measured 58 degrees , wrist flexion 41 degrees , pronation 83 degrees and supination 84 degrees . The Mayo Wrist Score showed 21% excellent, 58% good, 16% fair and 5% poor results.
Conclusion:
The treatment of unstable, dorsally dislocated, distal radius fractures AO types A3, C1 and C2, with a palmar placed 2.4 mm interlocking plate system and without additional treatment of the metaphyseal defects showed good radiological and functional results with minimal loss of reduction.
More Related Videos
10:36Vascularized Composite Hand Allograft Procurement and Preparation for Distal and Proximal Forearm Allotransplantation: A Stepwise Approach
Published on: May 23, 2025
15:11Surgical Fixation of Sternal Fractures: Preoperative Planning and a Safe Surgical Technique Using Locked Titanium Plates and Depth Limited Drilling
Published on: January 5, 2015
Related Concept Videos
Bones of the Upper Limb: Radius
The radius has a nail-shaped head, and a short...
Bones of the Upper Limb: Ulna
Fractures: Bone Repair
Minor fractures with no bone displacement are treated by immobilizing the fractured bone using a cast or splint. However, in the case of fractures with displaced bones, the broken bones are repositioned before immobilization to ensure successful healing without deformation and loss of function. The realignment of fractured bone ends is performed through a process called reduction. If the procedure...
Muscles of the Forearm that Move the Hand and Fingers
Anterior Compartment
The anterior compartment muscles originate from the humerus. They primarily function as flexors and are also known as flexor muscles. They typically insert on the carpals, metacarpals, and phalanges. The superficial layer includes the flexor carpi radialis,...